Charger access can follow a schedule instead of a single setting that applies around the clock. The Dynamic option in Charger scope lets you define two access levels, one for off-peak windows and one for the rest of the time, and the charger switches between them automatically.
Two scopes on a schedule: When Dynamic is selected, choose one of the operator's existing Off-Peak Schedules, an off-peak scope and a peak scope. Each scope can be Public, Account, Groups or Closed. Closed means no driver can start a session during that period.
Reuses existing schedules: The schedule is selected from the operator's saved Off-Peak Schedules (Operator → Off-Peak Schedules). Schedules are created and edited there, not from the charger scope dialog.
What drivers see: A short label on the charger reflects the driver's current access and when it changes, for example "Available until 18:00", "Available from 18:00" or "Not available to you." Two drivers may see different labels on the same charger depending on their group.
Active sessions are protected: A session already running when a period changes continues until the driver stops it. Only new sessions are affected by the schedule.
Account admins: Account admins can edit the schedule when a charger's scope is set to Dynamic.
Where to find it
Back Office → Chargers → Edit charger → Charger scope